Q1. Alternating Current has:
Candidate Answer - A changing polarity, an amplitude component and a frequency,
Result - Correct
Q2. Direct Current is a the flow of ___________, which travel in one direction only
Candidate Answer - Protons
Result - Incorrect
Q3. The measurable relationship between current, voltage, resistance and power is described in
Candidate Answer - Ohm's Law
Result - Correct
Q4. Electrical Resistance is a property a material possesses to __________ the flow of electricity
Candidate Answer - Restrict
Result - Correct
Q5. What is the resistance of a bulb with a current flow of 5amps with a voltage of 24Volts
Candidate Answer - 4.8 Ohms
Result - Correct
Q6. The sum of the individual voltage drops in a series circuit must be ______ the applied voltage
Candidate Answer - equal to
Result - Correct
Q7. The voltage applied to a DC Series Circuit that must equal the sum of the voltage drops with a circuit is known as
Candidate Answer - Kirchhoff law
Result - Correct
Q8. A resistor is defined as an electrical component designed to have a resistance against the flow of ___________
Candidate Answer - Electrons
Result - Correct
Q9. When circuit elements are connected so that two terminals are shared and voltage is common across the shared terminals this is called
Candidate Answer - Parallel
Result - Correct
Q10. An adjustable or variable resistor is known as a
Candidate Answer - Potentiometer
Result - Correct
Q11. A __________________ is a device placed in series with a power line which, when an excess amount of current is sensed, will open the power connection, thus protecting a circuit or system.
Candidate Answer - Circuit Breaker
Result - Correct
Q12. A bad connection or any point of resistance on a circuit will cause a
Candidate Answer - Voltage drop
Result - Correct
Q13. Where more than one ground path is created, and different paths create a voltage differential, this is known as a
Candidate Answer - Ground loop
Result - Correct
Q14. A fuse connected in-line at the battery is there to protect
Candidate Answer - The wire and equipment connected
Result - Incorrect
Q15. When connecting a high current device, connect a fuse at the battery no more than 25 cm from the battery and make sure it is
Candidate Answer - Before the bulkhead
Result - Correct
Q16. What are the main elements of a relay
Candidate Answer - Coil, spring, contacts
Result - Incorrect
Q17. Where a relay has extra contacts labelled 30, 85, 86 ,87 and 87a the relay will be a
Candidate Answer - Double pole double throw
Result - Incorrect
Q18. The process of changing AC current to DC current is known as
Candidate Answer - Rectification
Result - Correct
Q19. A battery can also be referred to as a
Candidate Answer - Capacitor
Result - Correct
Q20. Primary batteries can
Candidate Answer - Be recharged
Result - Incorrect
Q21. Using the wrong cable (too small) size for the type of application could cause the cable to
Candidate Answer - Overheat and melt
Result - Correct
Q22. What is an electrical two- terminal device which allows current to pass through it in one direction only
Candidate Answer - Diode
Result - Correct
Q23. A diode is used to:
Candidate Answer - Protect existing factory wiring systems
Result - Correct
Q24. When a diode conducts there will be a______ drop across it, and less voltage will be available for the equipment.
Candidate Answer - 0.7 volt
Result - Correct
Q25. A professional installation is not just about the quality of your work. It also includes
Candidate Answer - Your preparedness and professionalism
Result - Correct
Q26. When the amperage draw of a system exceeds 120% of the alternator’s maximum output, which components will sustain damage
Candidate Answer - The battery and alternator
Result - Correct
Q27. Can Bus wires are twisted to help reduce
Candidate Answer - Interference
Result - Correct
Q28. What component are we describing in the article below ‘An accelerant is ignited which in turn ignites the gas generating material, causing an explosion’
Candidate Answer - Hydrogen Cell
Result - Incorrect
Q29. It is always advisable to run power and signal leads away from each other. This is to avoid
Candidate Answer - Interference
Result - Correct
Q30. A good solder joint should be
Candidate Answer - Smooth, shiny and concave
Result - Correct
Q31. In case of any conflict when complying with installation instructions, which instruction take priority?
Candidate Answer - The vehicle manufacturer
Result - Correct
Q32. Where is the optimum position for an antenna to obtain the best signal
Candidate Answer - Roof of the vehicle
Result - Correct
Q33. Why must an installer abide by the EMC Directive
Candidate Answer - To comply with the law
Result - Correct
Q34. The main benefit of using an antenna analyser on an airwave device is:
Candidate Answer - The antenna can be tested regardless of whether the radio terminal is live on the network
Result - Correct
Q35. A risk assessment is a careful examination of aspects of work that could
Candidate Answer - Cause harm to people
Result - Correct
Q36. At the preinstallation stage after you have checked the condition of the interior, to prevent any damage to the vehicle you should
Candidate Answer - Fit seat covers and any other protective equipment
Result - Correct
Q37. Is it acceptable to install a transceiver or any other device in the load storage area of a vehicle
Candidate Answer - Yes, if it does not obstruct access to other items, and is safe for the device.
Result - Correct
Q38. A fuse is ideally installed as close to the power as possible
Candidate Answer - To ensure the cable and device are protected.
Result - Correct
Q39. You have just drilled a hole in a metal panel in the vehicle. The next step is:
Candidate Answer - Debur the hole and carefully remove any swarf
Result - Correct
Q40. Where is the optimum position of a separate microphone
Candidate Answer - On or near to the front centre interior light cluster
Result - Correct
Q41. You have a device which has a fuse installed on the device itself. Is it correct to install a separate fuse on the cable?
Candidate Answer - Yes, to protect the cable
Result - Correct
Q42. Should all equipment power supplies, whether taken from the ignition or battery circuits, be fused?
Candidate Answer - Yes all fuses must be protected by an adequate fuse of the correct rating
Result - Correct
Q43. Are you responsible for the installation of used equipment to be compliant with the latest relevant legislation
Candidate Answer - Yes, the installer is responsible
Result - Correct
Q44. What must the business provide to the technician before any work is carried out on a vehicle?
Candidate Answer - Suitable PPE
Result - Incorrect
Q45. When installing equipment into police vehicles, guidance is available from FCS1362 and from the Code of Practice from which organisation?
Candidate Answer -
Result - Incorrect