Q1. Alternating Current has:
Candidate Answer - A changing polarity, an amplitude component and a frequency,
Result - Correct
Q2. The measurable relationship between current, voltage, resistance and power is described in
Candidate Answer - Ohm's Law
Result - Correct
Q3. The conversion of electrical energy into another form of work is measured in
Candidate Answer - Watts
Result - Correct
Q4. You have a 55w bulb running a conventional 12v system, what will the current flow be?
Candidate Answer - 4.58 Amps
Result - Correct
Q5. The voltage applied to a DC Series Circuit that must equal the sum of the voltage drops with a circuit is known as
Candidate Answer - Kirchhoff law
Result - Correct
Q6. When circuit elements are connected so that two terminals are shared and voltage is common across the shared terminals this is called
Candidate Answer - Parallel
Result - Correct
Q7. An adjustable or variable resistor is known as a
Candidate Answer - Potentiometer
Result - Correct
Q8. Which component listed contains a wire or strip of metal that is installed in series with a power line that is designed to melt if it receives an excessive amount of current, is called
Candidate Answer - Fuse
Result - Correct
Q9. A bad connection or any point of resistance on a circuit will cause a
Candidate Answer - Voltage drop
Result - Correct
Q10. Adding up resistances in a series circuit will give the ________________ resistance
Candidate Answer - Total
Result - Correct
Q11. A ground loop creates interference. How is it created?
Candidate Answer - By any non zero resistances between the wiring to ground and each piece of equipment
Result - Correct
Q12. When connecting a high current device, connect a fuse at the battery no more than 25 cm from the battery and make sure it is
Candidate Answer - Before the bulkhead
Result - Correct
Q13. No current can flow in an
Candidate Answer - Open circuit
Result - Correct
Q14. What are the main elements of a relay
Candidate Answer - Coil, spring, contacts
Result - Correct
Q15. Whenever the relay has an INTERNAL SPIKE SUPPRESSION DIODE, to activate the relay
Candidate Answer - 85 must always be connected the Negative (-) terminal and 86 must always be connected to the Positive (+) terminal
Result - Correct
Q16. Where a relay has extra contacts labelled 30, 85, 86 ,87 and 87a the relay will be a
Candidate Answer - Double pole double throw
Result - Incorrect
Q17. The process of changing AC current to DC current is known as
Candidate Answer - Refraction
Result - Incorrect
Q18. A battery can also be referred to as a
Candidate Answer - Capacitor
Result - Correct
Q19. Primary batteries can
Candidate Answer - Deliver electrical energy but cannot be recharged
Result - Correct
Q20. What type of cable should NOT be used in a vehicle environment
Candidate Answer - Solid cable
Result - Correct
Q21. Using the wrong cable (too small) size for the type of application could cause the cable to
Candidate Answer - Overheat and melt
Result - Correct
Q22. In order to avoid self destruction, what is normally connected to an LED in series to limit the current across it
Candidate Answer - Resistor
Result - Correct
Q23. A professional installation is not just about the quality of your work. It also includes
Candidate Answer - Your preparedness and professionalism
Result - Correct
Q24. When the amperage draw of a system exceeds 120% of the alternator’s maximum output, which components will sustain damage
Candidate Answer - The battery and alternator
Result - Correct
Q25. Can Bus wires are twisted to help reduce
Candidate Answer - Interference
Result - Correct
Q26. What component are we describing in the article below ‘An accelerant is ignited which in turn ignites the gas generating material, causing an explosion’
Candidate Answer - Petrol Engine
Result - Incorrect
Q27. A good solder joint should be
Candidate Answer - Smooth, shiny and concave
Result - Correct
Q28. To avoid EMC issues it is advisable to use a product that has CE marking, what does CE stand for in English
Candidate Answer - European Conformity
Result - Correct
Q29. In case of any conflict when complying with installation instructions, which instruction take priority?
Candidate Answer - The vehicle manufacturer
Result - Correct
Q30. What does EMC stand for?
Candidate Answer - Electro Magnetic Compatibility
Result - Correct
Q31. Where is the optimum position for an antenna to obtain the best signal
Candidate Answer - Roof of the vehicle
Result - Correct
Q32. How much impedance should an ideal antenna cable have?
Candidate Answer - 50 Ohms
Result - Correct
Q33. The power supply cable you install should be
Candidate Answer - Cut to the correct length and as short as possible
Result - Correct
Q34. Why must an installer abide by the EMC Directive
Candidate Answer - To maintain warranties
Result - Incorrect
Q35. The main benefit of using an antenna analyser on an airwave device is:
Candidate Answer - The antenna can be tested regardless of whether the radio terminal is live on the network
Result - Correct
Q36. A GPS antenna needs to be installed:
Candidate Answer - With a clear view of the sky
Result - Correct
Q37. At the preinstallation stage after you have checked the condition of the interior, to prevent any damage to the vehicle you should
Candidate Answer - Fit seat covers and any other protective equipment
Result - Correct
Q38. A fuse is ideally installed as close to the power as possible
Candidate Answer - To ensure the cable and device are protected.
Result - Correct
Q39. You have a high current device to connect to the vehicle. You should take the power from:
Candidate Answer - The battery
Result - Correct
Q40. You have just drilled a hole in a metal panel in the vehicle. The next step is:
Candidate Answer - Debur the hole and carefully remove any swarf
Result - Correct
Q41. Where is the optimum position of a separate microphone
Candidate Answer - On the windscreen
Result - Incorrect
Q42. You have a device which has a fuse installed on the device itself. Is it correct to install a separate fuse on the cable?
Candidate Answer - Yes, to protect the cable
Result - Correct
Q43. Should all equipment power supplies, whether taken from the ignition or battery circuits, be fused?
Candidate Answer - Yes, all fuses must be protected by an adequate fuse of the correct rating
Result - Correct
Q44. Are you responsible for the installation of used equipment to be compliant with the latest relevant legislation
Candidate Answer - Yes, the installer is responsible
Result - Correct
Q45. What must the business provide to the technician before any work is carried out on a vehicle?
Candidate Answer - A risk assessment document
Result - Correct